Skip to content
| ZGSM
  • Home
  • About usExpand
    • Company Profile
    • Warranty term
    • Blogs
    • News
    • Privacy Policy
  • ProductsExpand
    • LED Street Light

      Solar Street Light

      Led Flood Light

      Solar Flood Light

      LED High Bay Light

      High Mast Light

      red green yellow LED Traffic Light

      LED Traffic Light

      tunnel lights

      LED Tunnel Light

      LED Garden Light

      LED Canopy Light

      Led Bollard Light

      adapter

      Lighting Accessories

  • SolutionExpand
    • Smart Systems

      Smart Systems

      Simulation Design

      Smart Financing

      Smart Financing

  • Applications
  • Case Studies
  • Videos
  • Contact
  • ENExpand
    • FR
    • ES
    • RU
| ZGSM
  • LED Floodlighting at the Jordanian Bazaar
  • LED Floodlighting at the Jordanian Bazaar-2
  • LED Floodlighting at the Jordanian Bazaar-3
  • LED Floodlighting at the Jordanian Bazaar
  • LED Floodlighting at the Jordanian Bazaar-2
  • LED Floodlighting at the Jordanian Bazaar-3

Series Zoom LED Floodlighting at the Jordanian Bazaar


The LED floodlighting project of Jordan bazaar adopts ZOOM series LED flood lights designed and produced by ZGSM. The power of the lamp is 400W, the color temperature is 4000K, the light-emitting angle is 90°, and the lamps are evenly installed on the bracket around the high mast to ensure the 360° full coverage of the lighting (High Mast Lighting).

As night fell, the LED floodlight turned on on time. It is carefully installed in various key locations of the market, and the powerful lighting ability instantly dispels the darkness. The bright and uniform light not only illuminates the bazaar, but also provides effective lighting for the passing highway. LED floodlighting provides a strong guaranty for the safety of the bazaar. The bright lights make the corners no longer hidden, effectively reducing potential safety hazards and making people feel more at ease when shopping and relaxing.

This LED floodlighting, with its excellent performance, has created a bright, warm, and safe nighttime environment for the Jordanian bazaar, becoming a crucial support for the market’s vibrancy and prosperity at night.

Download

datasheet installation Manual

Project details:

ProductModelCCT/ OpticsQuantity
400W LED FloodlightingZGSM-FL07-400XL4000K/90°40

.

Products Used

led flood

Series ZOOM Tool-less Led Flood Light

Video

Related Products

Series Glomax Professional LED Sports Field Lights

Series ALCA Cobra Head Street Light with Tool-Free Design

single arm post top light-06

Series Halo Single Arm & Double Arm Post Top LED Lights

ATEX approved LED Flood Light

Series Primo ATEX approved LED Flood Light

Related Projects

50 watt led flood light for building lighting in The Czech republic

Series HB 50 watt led flood light for building lighting in The Czech republic

stadium flood light for soccer field lighting in Thailand1

Series M stadium flood light for soccer field lighting in Thailand

best outdoor flood lights

Series H best outdoor flood lights for Football field lighting in Indonesia

high bay flood light in a factory in Bulgaria

Series HB high bay flood light in a factory in Bulgaria

Related Blogs

Street light light distribution

Light distribution of outdoor luminaire and their applications

Guide to get billboard illuminated correctly

footbal stadium

Guide for LED football pitch lighting – Stadium lights

Sports flood lights

Aim of sports flood lights – target aiming or degree aiming

People also ask

Outdoor areas and building facades: Used for large-area uniform lighting and facade wall washing in parks, gardens, sidewalks, building exterior walls, etc., emphasizing wide coverage, sufficient brightness and weather resistance. Common installation positions include walls, columns, eaves, ground bases, etc.

Commercial retail and display: Enhance the visibility and attractiveness of store fronts, windows and key displays, suitable for new product launches, promotions and other scenarios that require flexible lighting.

Sports and event venues: Provide high-illuminance and high-uniformity lighting for football fields, basketball courts, tennis courts, athletic fields, etc., and take into account color rendering and glare control.

Industry and warehousing logistics: large-area operation areas such as factories, workshops, warehouses, and docks, emphasizing high efficiency, energy saving, long life, and stability and reliability.

Urban infrastructure and transportation hubs: public spaces such as parking lots, stations, subway stations, bridges, and overpasses, taking into account functional lighting, safety, and image.

Billboard and landscape lighting: billboards, signs, sculptures, landscape avenues, trees, etc., highlight visual recognition and nighttime beauty, and often achieve dynamic effects with the control system

Glare evaluation is primarily based on Glare Rating (GR) (Reduce glare – UGR, GR and Ti in lighting design). The GR at any location on the field should be controlled to ≤50 (for broadcasting) or ≤55 (for local matches), with key viewing areas (such as behind the goal and the front of the sideline public areas) requiring particular attention. To ensure image quality, the vertical illuminance in the spectator area should be no less than 0.25 times the vertical illuminance of the field. These indicators should be included as constraints in the simulation and verification process during the design phase.

Uniformity is recommended to be controlled using two indicators: U1 = Emin/Emax and U2 = Emin/Eave. The horizontal illuminance uniformity of the playing field should be ≥0.5, and the uniformity of the key vertical plane facing the main camera should be ≥0.4; broadcasting/HD events usually require higher values ​​(e.g., U1h ≥ 0.60, U2h ≥ 0.80). Simultaneously, the illuminance change between adjacent grid points should not exceed 20%, and the ratio of average horizontal illuminance to average vertical illuminance should be between 0.5 and 2.0.

Illuminance levels and target values ​​should match the level of the event: approximately 200 lx for training/recreation, 500 lx for amateur matches, 750 lx for professional matches, 1000 lx for general TV broadcasting, and 1400–3500 lx for large-scale international HD broadcasting; the ratio of vertical illuminance to horizontal illuminance (Ev/Eh) is recommended to be approximately 0.5–0.75 to balance three-dimensionality and image quality.

Application ScenariosReference Illuminance
Industrial Plants and Workshops (General Areas)100–150 lx
Warehousing and Storage Yards150–300 lx
Parking Lots and Passageways50–100 lx
Petrochemical Plant Areas200–500 lx
Tunnels (General)100–300 lx
Dock Decks/Storage Yards≥50 lx
Building Facade Floodlighting (Decorative)15–450 lx
Sign/Billboard Floodlighting100–500 lx

Post Tags: #Flood Light#LED Floodlighting

Get In Touch

We're always excited about your message, so feel free to get in touch.
We will reply to you ASAP.

Category

LED Street Light
LED Flood Light
LED High Bay Light
LED Canopy Light
LED Garden Light
Solar Street Light
High Mast Light
LED Traffic Light
Lighting Accessories

Don't Want to Miss Anything?

Be the first to get updates and information about products and services.

  • Facebook
  • Twitter
  • Instagram
  • YouTube

© 2005 - 2025 · ZGSM Tech Warranty Terms | Privacy

Language Selection ES | FR | RU

  • Home
  • About us
    • Company Profile
    • Warranty term
    • Blogs
    • News
    • Privacy Policy
  • Products
    • LED Street Light

      Solar Street Light

      Led Flood Light

      Solar Flood Light

      LED High Bay Light

      High Mast Light

      red green yellow LED Traffic Light

      LED Traffic Light

      tunnel lights

      LED Tunnel Light

      LED Garden Light

      LED Canopy Light

      Led Bollard Light

      adapter

      Lighting Accessories

  • Solution
    • Smart Systems

      Smart Systems

      Simulation Design

      Smart Financing

      Smart Financing

  • Applications
  • Case Studies
  • Videos
  • Contact
Search