Skip to content
| ZGSM
  • Home
  • About usExpand
    • Company Profile
    • Warranty term
    • Blogs
    • News
    • Privacy Policy
  • ProductsExpand
    • LED Street Light

      Solar Street Light

      Led Flood Light

      Solar Flood Light

      LED High Bay Light

      High Mast Light

      red green yellow LED Traffic Light

      LED Traffic Light

      tunnel lights

      LED Tunnel Light

      LED Garden Light

      LED Canopy Light

      Led Bollard Light

      adapter

      Lighting Accessories

  • SolutionExpand
    • Smart Systems

      Smart Systems

      Simulation Design

      Smart Financing

      Smart Financing

  • Applications
  • Case Studies
  • Videos
  • Contact
  • ENExpand
    • FR
    • ES
    • RU
| ZGSM

How Long do Led Lights Last ?

How Long do Led Lights Last ?

table of Contents
  1. Introduction
  2. What's LM-80 and what's it used for?
    1. LM-80 test method
    2. LM-80 test result and report
  3. What should a qualified LM-80 include?
  4. What is TM-21?
  5. What does LxxByy mean?
  6. Summary
  7. Rated Products
  8. Related Blogs
  9. Related Cases
  10. People also ask
  11. Author introduction

Introduction

One main advantage of LED light is its long lifespan. This is based on the fact during the usage of LED lights during the last decades. Therefore LED lights are known for their long lifespan, and many manufacturers directly print the expected lifespan on the packaging. The LED Light Lifetime is expected to range from 5 to 20 years, but the actual lifespan of LEDs is far beyond manufacturers’ simple estimates. Many factors can affect the actual lifespan of LEDs, including high heat, high frequency of use, and operating LED lights at higher than expected currents. So, how long can LED lights last?
The actual situation is that the lifespan of LED lights is usually around 4 to 6 years. For example, LED lights can last for 10 years, but if used frequently outdoors in extreme heat, they may only last for 8 years; If the lamp is placed at room temperature and rarely used, it may last for 12 years. However, it should also be noted that even if the LED lamp ( Explore different types of street LED lamps. ) does reach the manufacturer’s claimed lifespan, the lamp will experience light decay, which will reduce the light output of the LED over time.

We here will explain this based on lumen maintenance of LEDs over time and its lifetime when it’s applied in LED products. LM-80 report includes the lumen maintenance information of LEDs, while the TM-21 can be used to calculate the lifetime of the LED light. Besides, now LxxByy report of LEDs is also used for tenders, which is about the lifetime of LEDs as well. So we will you know the details about LM-80, TM-21, and LxxByy reports in this article.

lifetime of leds and led light-2
lifetime of leds and led light-3

What’s LM-80 and what’s it used for?

LM-80 report is the lumen maintenance test report of the LED device (LED Package, Array/Module, or COB) issued by the laboratory according to the IES LM-80 test method and standard. The LM-80 report can be used for energy efficiency certification of end products, such as ENERGY STAR certification and DLC certification for the Americas market.

In this report, the LED devices will be tested at one current and at least three temperatures (55, 85, and optional). And the test will be done at least 6,000 hours, therefore test time, LED temperature, and LED current are three main factors that we should consider in the LM-80 test.

LM-80 test method

LM-80 test should last for at least 6000 hours and it should be carried in three different temperatures and different drive currents of LEDs if needed. Therefore the three main factors refer to in the LM-80 test are time, temperature, and LED drive current.

 1. Test time requirement (related to prediction accuracy)

The LM-80 test should be carried out for at least 6,000 hours and the recommended time is 10,000 hours. By this, you will obtain the LED light attenuation information every 1,000 hours. The shorter the interval time is, the more the accuracy of the prediction time is.

2. Test temperature control

The LEDs will be tested in three groups, and the temperature at the Ts point of each group was different. Normally 55℃ and 85℃ are mandatory, while another temperature is optional. For example, Lumileds choose 105℃ as their 3rd temperature.

  • During the process, the standard allowable temperature tolerance is -2°C.
  • During the test, the ambient temperature of Tair near the sample must be monitored. And it cannot be lower than Ts by more than 5°C.

The Ts of each sample should be monitored in real-time during the test. Below is the Ts point for your reference.

3. LED drive current

Normally the higher the drive current, the higher the luminous flux attenuation will be. Because the LED drive current of LED light is based on the manufacturer’s design. Some will be with high drive current to get high wattage with the same quantity of LEDs as others, while others want to use low drive current to power the LEDs so the efficacy of LED light is much higher. Then we should consider the LED drive current when we are doing the LM-80 test.

After every 1000 hours of the test period, the photometric test needs to be carried out under the condition of 25℃±2℃.

LM-80 test result and report

We will get photometric test results after every 1000 hours test period. The photometric test results include meaning, median, standard deviation, maximum, and minimum of normalized flux at each temperature and each sample from the initial for every 1000 hours. And chromaticity shift reported over the measurement time should also be included.

After getting the test results, we calculate the 70% lumen maintenance rate at every temperature experiment over time under ENERGY STAR standard, According to the formula, the equation is y=mx+b, B=exp(b), a=-m. Use Exponential Least Squares Curve-Fit to get Slope m and Intercept b, when calculating m and b. Below is the curve and this can also be achieved when we put the time, temperature, and lumen maintenance result into the TM-21 table.

What should a qualified LM-80 include?

  • Luminous flux attenuation percentage and attenuation curve of test products
  • Test product for color drift, i.e. color difference between 6000 hours and 0 hours
  • Whether the report is authorized and meets the standard testing requirements
  • Whether the number of samples meets the requirements for energy efficiency certification of finished products
  • Whether the color difference meets the standard requirements
  • Whether the percentage of decay and its estimated life can meet the customer’s declared needs

What is TM-21?

How to calculate the lifetime of LED light? It’s the life estimation method mainly used for LED packaging products at present. The finished LED light can claim its lifetime L70* according to this method.

*L70 is the time when the lumen output of LED light retains 70% of its initial lumen output.

In other words, LED light rated L70 > 50,000 hours, then would retain 70% of its light output after 50,000 hours. Whereas a LED light rated L70>100,000 hours, will retain 70% of its output after 100,000 hours. Then we will say that the lifetime of this LED light is over 100,000hrs. Because when the lumen output is under 70% of the initial flux, we think it’s time to replace it with a new one.

When the LED device is applied to the finished LED light, the temperature of its corresponding point(Ts) and the drive current of LEDs are tested.

By comparing the temperature and current of LED light with the one in the LM-80 report, the data in LM-80 can be adopted if the conditions in the LM80 report are more severe. And we can download the TM-21 table at: www.energystar.gov. And this form should be used in conjunction with the LM-80.

Take our Rifle series LED Street Light 100W as an example.

  1. We need to put the LM80 result(red column) into the TM21 table. We will get the TM21 table 1 at 60mA and 70℃&85℃&105℃, TM21 table 2 at 100mA and 85℃&105℃, and TM21 table 3 at 200mA and 85℃&105℃.
  2. Ts of ZGSM-ST17-100M is 60.5℃ and the LED drive current is 68, then we can fill TM21 table 2 with this information. Because the Ts and drive current of table 2 are more severe than these of ZGSM-ST17-100M.
  3. We can get the lumen maintenance rate in the pink column.

The results are as follows.

  • After 100000 hours, the lumen maintenance rate is 74.19%.
  • We can claim that our Rifle series has L70>102,000hrs.

But if the Ts is 90℃, while others are all same, then the result will be different. Because the result is based on curves both at 85℃ and curves at 105℃.

What does LxxByy mean?

Normally it’s expressed by an ‘Lxx Byy @ zz,000 hours’ rating, which defines the rate at which luminous flux depreciates over time. The xx digits refer to the amount of maintenance luminous flux, which is simply 100% minus the ratio of initial flux that has depreciated. The yy digits refer to the ratio of LEDs within the total quantity that would not meet the xx target maintenance flux. So, a LED with a lumen maintenance specification of L90 B10 @ 80,000 hours refers to 10% depreciation (i.e. 90% maintenance) of flux over that 80,000 hours and clarifies that at least 90% of those LEDs would achieve that 90% or greater maintenance flux (i.e. 10% of total LEDs would depreciate by more than 10%). Lumen maintenance specifications must be derived by the industry-standard TM-21 projection method, which uses data from long-term LED testing (LM-80 report, with a minimum of 6,000 hours testing) and in-situ luminaire temperature testing.

Summary

LM-80 report includes the lumen maintenance information of LEDs. The LEDs will be tested at different drive currents of LEDs, at 3 different temperatures, every 1000 hours. We will get the lumen maintenance information of LEDs at xxxmA, at yyy hours, at zzz ℃. This is about the lifetime of LEDs.

TM-21 report is used to calculate the lifetime of the LED light. When the LEDs are used on lamps, the lifetime of LED lights is partly determined by the lifetime of LEDs. How to get the lifetime of LED light? We have to put the LM80 result(lumen maintenance information) into the TM21 table. Because the main factors regarding lumen maintenance are LED drive current and temperature. So we should put Ts and drive current of LED light into right TM21 table. And TM21 table will automatically compare the Ts of LED lights and drive currents of LED lights with the one in the LM80- report. And finally, we can get the lifetime (L70) of the LED light.

LxxByy report differs from the LM80 report and TM-21 report. But it’s also regarding the lifetime of LEDs. And it’s becoming more and more common in tenders’ requirements.

We can see that these three reports LM80, TM21 and LxxByy are all related to the life of LEDs, and the lifetime of LED lamps is mainly related to temperature and drive current. Therefore, for our products including LED street lights, flood lights, high bay lights and gas station lights, we have strict requirements on the temperature of the lamps and the drive current of the LEDs, so as to prolong the service life of the LED lamps as much as possible.

Rated Products

street lighting led

Series Nova Competitive Led Road Light

residential led street lights

Series Kmini2 Eco But Quality Ensured Led Light Street

led street light with enec+

Series Rifle Class I/II Street Lamp

UFO High Bay Light

Series Helios 190LM/W UFO High Bay Light

led flood

Series ZOOM Tool-less Led Flood Light

ATEX Led Canopy Light

Series Primo ATEX Led Canopy Light

hanging street lights

Series L Flexible Mounted Hanging Street Lights

Toolless Open Street Led Light

Series K Toolless Open Street Led Light

Related Blogs

How to Calculate Lighting Uniformity?

TagsFlood Light
ik rating

IK rating-important factor of LED light

TagsIK

What are the common quality problems of LED street light?

TagsLED Street Light

Class I vs Class II vs Class III, or Class 1 vs Class 2

TagsClass rating
things about led street light

Several things you need to know about LED Street Light

TagsLED Street Light
smart control street light

Some Things about Street Light Control System

TagsLED Street Light
street light cost

How much does a street light cost?

TagsLED Street Light
something about leds

Something you should know about LEDs

TagsLEDs
street light with photocell

11 Things You Need Know About LED Street Light with Photocell

TagsLED Street Light
Street light light distribution

Light distribution of outdoor luminaire and their applications

TagsLight distribution

Related Cases

led canopy lights for petrol station

Series H led canopy lights for petrol station in Spain

200W LED High Bay Light

Series H led high bay light in a workshop in Canada

hanging street lamp

Series L hanging street lamp in a Logistics center in UAE

L Series Pendant Road Light

Series L modern street lamp in City road in Italy

decorative street lighting fixtures

Series K motion sensor led street light on a mountain road in Norway

led street light 150w

Series H Street Lighting On Main Roads in JKR Kayu Ara of Malaysia

led street light price

Series H Led Roadway Light On a City road in Iraq

Streetlight Led

Series H Streetlight Led On The Seaside Urban Road In Qingdao of China

Residential Led Street Lights

Series H Residential Led Street Lights On Community Road In Malaysia

Highway Lighting

Series H Led Highway Lighting in JKR Bukit Nenas of Malaysia

People also ask

LED light bulbs will not typically need replacement for at least 20 years. That’s 20 years when you don’t have to worry about replacing a bulb, and 20 years where your facility’s maintenance staff can focus on other chores. However many factors can affect the actual lifetime of LED lights, including temperature, switching frequency, service time, power quality, and drive current. So, how long will LEDs last? In general, the average life of LED lamps is usually 3 to 10 years, or longer, such as L70>100000hrs lamps, the theoretical lifespan of 22 years. But as we said, actual lifespan depends on many factors, and 10 years is a relatively conservative life expectancy.

Around 50,000 hours of illumination are provided by LED bulbs, with some brands offering up to 100,000 hours. In general, LEDs should last you for slightly under 14 years if you use them for 10 hours per day.

The most frequent causes of LED failure include excessive voltage, faulty connections, the use of an unsuitable dimmer control, and recessed illumination. Other factors include overheating resulting from improper usage of fixtures or a defective batch of lightbulbs!

LEDs are the most efficient light source currently available. LEDs also provide a significant benefit in terms of their durability. During the duration of use, the light output of the LEDs gradually declines. Consequently, LxBy metrics such as L90B10, L80B10, and L70B50 are used to represent the lifespan of LED luminaires.
The LxBy parameter determines when the luminaire’s lifespan will end and its operational margin of error. The LxBy terminology standard contains two indications. This is why its reading is broken into Lx and By sections. The L value denotes the minimum luminous flux that must be maintained for a certain length of time. The B number represents the rate of error. This is the amount of time required for y percent of LEDs to attain x percent of the original flux at the maximum ambient temperature given.
In a luminaire designated as L80B10, 50,000 hours, for instance, after 50,000 hours (about 16 years), 10% of the LEDs will emit less than 80% of their original luminous flux. The luminous flux of 90 percent of the LEDs is maintained such that it does not fall below 80 percent of the starting flux.
If the L70B50, 50,000-hour criterion is met, then after 50,000 hours, only 50 percent of the LEDs retain more than 70 percent of their original lumen output. Therefore, the light decay of L70B50 is quicker than that of L80B10. If you must select between the two, the L80B10 is the superior option
In LED lighting applications, a high L value and a low B value are preferred. Thus, it is feasible to conclude that L100B0 is the best. However, it cannot be accomplished. It is normal for the light output of LEDs to diminish with time.
The threshold for human perception is a 30 percent reduction in initial luminous flux. Therefore, the commonly accepted lifespan measurement for LED light sources is when 70 percent of the original flux remains. At 80 percent of their original luminous flux, it is suggested to replace the LED lighting fixtures used for interior illumination. The suggested ratio for street illumination is 90 percent.

Author introduction

About the author
Author

Hello Customers,

My name is Taylor Gong, I’m the product manager of ZGSM Tech. I have been in the LED lights industry for more than 13 years. Good at lighting design, roadway light system configuration, and bidding technology support. Feel free to contact us. I’m happy to provide you with the best service and products.

Email: [email protected] | WhatsApp: +8615068758483

  • Mail
  • Facebook
  • Twitter
  • YouTube
  • Instagram
  • LinkedIn
  • Pinterest


Post Tags: #Lifetime

Get In Touch

We're always excited about your message,
so feel free to get in touch, we will reply to you ASAP.

Category

LED Street Light
LED Flood Light
LED High Bay Light
LED Canopy Light
LED Garden Light
Solar Street Light
High Mast Light
LED Traffic Light
Lighting Accessories

Don't Want to Miss Anything?

Be the first to get updates and information about products and services.

  • Facebook
  • Twitter
  • Instagram
  • YouTube

© 2005 - 2025 · ZGSM Tech Warranty Terms | Privacy

Language Selection ES | FR | RU

  • Home
  • About us
    • Company Profile
    • Warranty term
    • Blogs
    • News
    • Privacy Policy
  • Products
    • LED Street Light

      Solar Street Light

      Led Flood Light

      Solar Flood Light

      LED High Bay Light

      High Mast Light

      red green yellow LED Traffic Light

      LED Traffic Light

      tunnel lights

      LED Tunnel Light

      LED Garden Light

      LED Canopy Light

      Led Bollard Light

      adapter

      Lighting Accessories

  • Solution
    • Smart Systems

      Smart Systems

      Simulation Design

      Smart Financing

      Smart Financing

  • Applications
  • Case Studies
  • Videos
  • Contact
Search